Skip to content
REDSTICK⌕

Compare · job: roof wind load design for roof systems and edge metal · stage: envelope

Roof wind load design for roof systems and edge metal, side by side

Every tool on the record for roof wind load design for roof systems and edge metal: 5 software tools, from ANSI/SPRI/FM 4435/ES-1 Wind Calculator, MF Windsog, Roof Wind Designer and Wind load calculator for roof and parapet cladding onwards, in alphabetical order. 1 has a free plan. 5 carry an assessment of where they fit on a job and the catch. Each was read at the maker's own source, most recently on 19 November 2026.

ComparingAll 5 toolsChoose which
Show
Scroll right for the rest
Fact
RS-R2583 · SaaS · Tremco Roofing and Building MaintenanceANSI/SPRI/FM 4435/ES-1 Wind Calculator
RS-R2610 · SaaS · Markus Friedrich Datentechnik (MF Dach)MF Windsog
RS-R1807 · SaaS · National Roofing Contractors Association (NRCA)Roof Wind Designer
RS-R2624 · SaaS · National Research Council CanadaWind load calculator for roof and parapet cladding
RS-R2625 · SaaS · National Research Council CanadaWind Uplift Resistance Calculator
At a glance
What it doesA web calculator for the wind design of a low-slope roof's edge metal under ANSI/SPRI/FM 4435/ES-1. You enter the building height, risk category, exposure (B, C or D), whether the edge is a fascia or a coping, and the ZIP code.Desktop software that works out wind uplift on a flat roof and the fixings needed to hold the roof build-up down. You draw the roof outline with cut-outs and upstands, pick a fixing method (mechanical fixing at seams or in the field, adhesive, ballast or a mix), and it gives a plan of the wind zones, a fixing layout, a material list and the calculation for the file. The maker lists DIN EN 1991-1-4, the Eurocode for several countries, the German roofing trade's flat roof rules, Swiss SIA and Austrian standards.A web calculator that works out the design wind loads on a roof to the ASCE 7 standard (2005, 2010, 2016 or 2022 edition) and turns them into minimum recommended wind resistance loads for the roof system and for edge metal flashing, so a roof system with a matching wind rating can be chosen.An online calculator from Canada's National Research Council that works out wind loads on roof cladding and parapet cladding, and design values for modular green roofs, to the National Building Code of Canada. It works per roof zone on a unit tributary area, to ultimate limit states.An online calculator from Canada's National Research Council that turns the lab result of a CSA A123.21 dynamic wind uplift test on a low-slope membrane roof into a design resistance, using the resistance factor in the National Building Code of Canada.
Who it's forRoofing contractors and specifiers choosing fascia or coping for a low-slope roof in the US.Roofing contractors and roof planners who must show how a flat roof is held down against wind.Roofing contractors, roof consultants and designers working to US building codes on low rise and mid rise buildings.Roof designers, consultants and roofing contractors working to the Canadian building code.Roof system makers, consultants and designers choosing a membrane roof assembly for a wind load in Canada.
The catchIt works from a US ZIP code. The page does not say what the result shows.No price on the maker's page. Denmark's standard is listed as a beta.It covers only the ASCE 7 methods for common building types and heights, so unusual buildings still need an engineer, and it gives loads, not a manufacturer's approved assembly.Only for buildings with a reference height from 9 m to 46 m, not on a hill or escarpment, and lower than their smallest plan dimension. A licence has to be accepted before use.Only for low-slope membrane roofs put through the CSA A123.21 lab method, and it needs the calibrated lab report. Above 11.5 kPa it needs results from three identical specimens. A licence has to be accepted before use.
AssessmentTremco's calculator works out the wind design of a low-slope roof's fascia or coping to ANSI/SPRI/FM 4435/ES-1 from a US ZIP code, and the page does not say what the result shows.MF Dach's desktop program gives the wind zone plan, fixing layout and material list for a flat roof to DIN EN 1991-1-4, German, Swiss and Austrian rules, with no price published.NRCA's Roof Wind Designer turns ASCE 7 wind loads into the rating a roof system and its edge metal need; free at present, US practice, common building types only.The National Research Council Canada's calculator gives wind loads on roof and parapet cladding to the National Building Code of Canada, for buildings with a reference height of 9 m to 46 m only.Canada's National Research Council turns a CSA A123.21 lab result for a low-slope membrane roof into a design resistance under the National Building Code of Canada, once a licence is accepted.
Buying it
Price shapeNot publishedNot publishedFreeNot publishedNot published
PriceNo price shown on the page.No price published.Free at present; registration offered.No price stated on the page.No price stated on the page.
Released-To check-To check-To checkMar 2021-To check
MakerTremco Roofing and Building MaintenanceMarkus Friedrich Datentechnik (MF Dach) · GermanyNational Roofing Contractors Association (NRCA)National Research Council Canada · CanadaNational Research Council Canada · Canada

Every tick links to where we read it. “Not published” means the maker doesn’t say, not that it can’t. A maker’s figure is the maker’s claim, read at its source; we have not measured it. They are in alphabetical order, never by who pays.