Skip to content
REDSTICK⌕
RobotConcreteMonitoring concrete curing and strength

HCS concrete sensors (T1 Bluetooth and T2 long range)

Sensors tied to the rebar before the pour that record concrete strength and temperature every 15 minutes for 60 days, and the TH1 also humidity every 6 hours. TH1 is read by Bluetooth on site; T2 sends to cloud software through a gateway rented from Hilti.

Review no.
RS-R143
Revision
C
Read at source
16 Nov 2026
Disclosure
None
Method
Read at the maker’s own source. Redstick has not used it.

Assessment

Not a replacement for anything: this is new tech alongside the old route of cube tests at 7, 14 and 28 days. The big win is confirming strength earlier than the standard timeframes, so formwork can be struck sooner and the programme saved. Tied to the rebar and logging every 15 minutes for 60 days: T1 is read by Bluetooth on site, T2 sends to the cloud through a gateway rented from Hilti. The catch: it only counts if the temporary works designer and the engineer have written strength-based striking, using this method, into the striking criteria before the pour. It needs calibrating to each mix, and cubes are still taken to check it. Without that sign-off, a sensor reading is not a reason to strike.

The catch

Strength may need a lab calibration for the mix. The T2 gateway is rented from Hilti.

Who forContractors and site engineers timing formwork striking and loading.
By whomHilti
Liechtenstein
hilti.co.uk ↗
Releasednot stated by the maker
Sold in
Europe
  • United Kingdom: on sale
North America
  • Canada: on sale
PricePurchaseFrom GBP 171 per T1 sensor (Hilti UK list, before account pricing). T2 on request.

What it replaces

Cube breaks and manual temperature readings.

Who else does it

Compare all 8 for monitoring concrete curing and strength side by side →

From people who've worked with it

None yet. If you’ve used it on a job, yours could be the first.

Worked with HCS concrete sensors (T1 Bluetooth and T2 long range)? Tell us how it went

Your own experience, in your own words: what you used it for, what it did well, what you’d warn someone about. John reads every report before anything goes on the page, and it goes on under your name, role and company, dated. No star ratings.

Source and revisions

Source: HCS T1 Concrete sensors (Bluetooth) - Hilti UK

Availability read at: Canada

RevDateChange
C9 Nov 2026Re-read at source (hunt run 2026-11-09): Hilti UK now sells the Bluetooth sensor as HCS TH1, adding humidity
B8 Nov 2026Assessment written by John: now Reviewed.
A8 Nov 2026First read at source (hunt run 2026-11-08d).

Are you the maker?

This listing is free and always will be: no maker pays to be listed or placed. If something here is wrong, tell us at hello@redstick.io and we’ll correct it, with the change dated in the revisions above. To link to this page from your own site, copy the badge below.

Listed on Redstick
<a href="https://redstick.io/reviews/hcs-concrete-sensors"><img src="https://redstick.io/badge.svg" alt="Listed on Redstick" width="180" height="44"></a>