Every tool on the record for finding leaks in flat roofs and waterproofing (leak detection): 7 software tools, from BMI FeuchteSensor, ISOVER GUARD SYSTEM, ProGeo smartex and SikaRoof Monitoring System onwards, in alphabetical order. On the record so far, none is shown on sale in the UK and between them they are sold in 3 countries. 6 carry an assessment of where they fit on a job and the catch. Each was read at the maker's own source, most recently on 14 November 2026.

ComparingAll 7 toolsChoose which
Show
Scroll right for the rest
Fact
RS-R1785 · SaaS · BMI GroupBMI FeuchteSensor
RS-R2070 · SaaS · Saint-Gobain ISOVERISOVER GUARD SYSTEM
RS-R369 · SaaS · ProGeo MonitoringProGeo smartex
RS-R1067 · SaaS · SikaSikaRoof Monitoring System
RS-R1818 · SaaS · Sita BauelementeVaruna Regenwächter and Hydrosensor
RS-R386 · SaaS · VILPEVILPE Sense
At a glance
What it doesHumidity sensors placed in a flat roof build-up, on new or refurbished roofs, that track moisture in the roof over time; the readings from each sensor are checked remotely in a web browser to see whether the roof is still watertight and when repairs will be due.Sensors fitted in a flat roof build-up that measure moisture and temperature, with a dashboard and real-time notifications, so a leak or wet insulation is spotted early and the right drying method can be chosen after water damage.A permanent leak monitoring system for flat roofs: sensor matrices, cables or point sensors under the waterproofing, a measuring unit, and a web portal that shows moisture over time and raises alarms.A modular, battery-powered sensor system for flat roofs that tracks moisture, temperature and humidity, finds water on the vapour barrier and sends email alerts, with the data on screen for maintenance planning.Three systems: a scanner that finds holes in a waterproofing membrane, sensors built into conventional and inverted roofs to watch for moisture, and moisture monitoring for mass timber buildings.Two connected sensors for flat roofs: the Regenwächter watches the water level on the roof and warns when it gets critical, and the Hydrosensor sits under the insulation and reports moisture or leaks, with alerts by SMS, email or an online dashboard.Wireless moisture and temperature sensors placed in roof insulation, a base station, and a cloud service with a moisture map and email alarms; an optional set runs a roof fan to dry the structure.
Who it's forFlat roof owners, roofing contractors and facility managers who want to know early if water is getting into a roof, particularly on Austrian projects working to ONORM usage categories.Owners and facility managers of industrial, office and high-rise residential buildings with flat roofs, and the roofers who fit them.Building owners, designers and roofing contractors on flat, green and solar roofs, including retrofit warm roofs.Building owners, facilities and asset managers and roofing contractors with flat roofs, new or refurbished.Roofing and waterproofing contractors, envelope consultants and building owners, especially on roofs that need a RoofStar warranty in British Columbia.Roofing contractors offering monitoring to their clients, facility managers and owners of flat roofed buildings.Building owners and property managers of commercial and industrial buildings, and the roofers fitting new or refurbished roofs.
The catchOne sensor covers only about 100 to 200 m2, so a large roof needs many, and the maker does not say how the sensor measures or whether it sends alerts.Each system covers only up to 200 m2 of roof, so large roofs need several, and the sensors have to be built into the roof.The precise-location sensor matrix (smartex mx) goes under the membrane when the roof is built or replaced and is for roofs from 250 square metres; the retrofit point sensor and the cable give only moisture readings or an approximate location. Needs power and a data connection on site.Sold as part of Sika's roofing offer; the page does not say whether it works on other makers' membranes, what the software costs to run, or how precisely it locates a leak.Sold by quote; how the monitoring software and alerts work is not set out on the pages read.Each sensor watches the spot where it is fitted, so coverage of a large roof depends on how many are installed.Sensors have to go into the insulation, so it is fitted when a roof is built or opened up; the maker's spacing is ten sensors per 200 square metres. It finds moisture by area, not the exact hole.
AssessmentReplaces finding the leak when it comes through the ceiling, and the one-off moisture test before the floor goes down. Sensors that sit in the roof or the slab and report moisture over time, with alarms. The win is the leak found early and a dated record. BMI's FeuchteSensor tracks moisture in the build-up in a browser, one sensor to about 100 to 200 m2; alerts not stated. The catch: they go in when the roof or slab is built or opened, and each works only with its own maker's kit.-To checkReplaces finding the leak when it comes through the ceiling, and the one-off moisture test before the floor goes down. Sensors that sit in the roof or the slab and report moisture over time, with alarms. The win is the leak found early and a dated record. ProGeo smartex puts a sensor matrix under the membrane to locate leaks precisely, for roofs from 250 m2. The catch: they go in when the roof or slab is built or opened, and each works only with its own maker's kit.Replaces the camera roll, the inspection pad and the archive boxes in the loft. Photos, surveys and certificates kept as a dated record. SikaRoof Monitoring tracks moisture and finds water under a flat roof; part of Sika's roofing offer. The catch: several are services or industry tools rather than site apps, and most prices are by quote.Replaces the camera roll, the inspection pad and the archive boxes in the loft. Photos, surveys and certificates kept as a dated record. SMT Research finds holes in membranes and monitors roof moisture with built-in sensors; by quote. The catch: several are services or industry tools rather than site apps, and most prices are by quote.Replaces finding the leak when it comes through the ceiling, and the one-off moisture test before the floor goes down. Sensors that sit in the roof or the slab and report moisture over time, with alarms. The win is the leak found early and a dated record. Sita's Varuna watches ponding water on the roof and moisture under the insulation, with SMS and email alerts. The catch: they go in when the roof or slab is built or opened, and each works only with its own maker's kit.Replaces finding the leak when it comes through the ceiling, and the one-off moisture test before the floor goes down. Sensors that sit in the roof or the slab and report moisture over time, with alarms. The win is the leak found early and a dated record. VILPE Sense puts wireless sensors in the insulation, with an optional fan to dry the roof. The catch: they go in when the roof or slab is built or opened, and each works only with its own maker's kit.
Buying it
Sold in-To checkGermany-To checkIrelandCanada-To check-To check
Price shapeNot publishedNot publishedBy quoteNot publishedBy quoteNot publishedNot published
PricePrice not published; contact BMI's humidity sensor account manager.Price not published.No price published; by enquiry to ProGeo.No price published; by enquiry to Sika.Quote only; DigiScan scanner can be bought on its own and TimberCast comes as a self-install kit.Price not published.No price or subscription terms published; by enquiry to VILPE.
MakerBMI GroupSaint-Gobain ISOVERProGeo Monitoring · GermanySikaSMT Research Ltd · CanadaSita Bauelemente · GermanyVILPE · Finland

Every tick links to where we read it. “Not published” means the maker doesn’t say, not that it can’t. A maker’s figure is the maker’s claim, read at its source; we have not measured it. They are in alphabetical order, never by who pays.